Hi,
We're looking for a low-latency 2.4GHz solution (not BLE) and the nRF51822 is oft-quoted as providing low latency, but what are the typical ms figures we could achieve...
Hello all,
in my previous question (Switch between applications (multiple services.h)) I got the advice to merge my two services into one service, including a HID over...
I am trying to create an nRF8001 based application that will broadcast battery levels (pipes broadcast, set), and give out temperature data (pipe indicate - TX_ACK) to connected...
An external PA/LNA is used to extend range of nRF51822, and S110 is used for BLE, How to switch between PA and LNA? and how to disable PA/LNA when there isn't transceiving...
Hi...
Can anybody help me to run ble_peripheral example (ble_app_hrs for S130). I have build and load the code successfully but cant see the advertisement. But while debugging...
1.Profile
During connection procedure of BLE, there are three packages: SCAN_REQ, SCAN_RSP 和 CONNECT_REQ。
SCAN_REQ: Scan request, issued by MASTER DEVICE, send to SLAVE DEVICE,sent by the Link Layer…
1.Profile
MTU: ATT Maximum Transmission Unit (MTU) is the maximum length of an ATT packet. The ATT MTU is defined by the L2CAP and can be
anywhere between 23 and infinity. The implementation of the…
Today I tried to find the better ways to debug program on nRF52840 PDK from CLI on linux.
The ways that I tried
[Failed] openocd (both stlink and jlink) & gdb
[Succeeded] JLink & JLinkGDBServer &…
This blog series was created as an attempt to fill in the gap between how Bluetooth Smart is described in the spec and how you can use our APIs and event from our softdevice to do what defined in the spec…
Important updates:
Due to erratum 84 (COMP: ISOURCE not functional), capacitive sensing using the relaxation oscillator method is not usable in a real product with the nRF52832, as it will only work reliably…
This blog series was created as an attempt to fill in the gap between how Bluetooth Smart is defined in the spec and how you can use our APIs and event from our softdevice to do what defined in the spec…
###Other relevant posts
For an overview of current measurement basics, see this post: Introduction
For a concise guide to setting up measurement equipment with the nRF52832 development kit, see this…
###Other relevant posts
For an overview of current measurement basics, see this post: Introduction
A post that describes how to measure current on the nRF52821 Engineering B with SoftDevice s132 v2…
###Other relevant posts
A concise guide to equipment setup, and how to use the development kit for current measurements can be found here: Measuring current with PCA10040 v0.9.0
A post that describes…