I use the LED onoff example of the Nordic BLE Mesh template (Version : 5.0), using two nodes (One Client, One Server). The nodes are already Provisioned.
I want to know...
Hello,
I am a firmware engineer in taiwan.
I already use nRF52820 to finish a case. This case have DFU function. The DFU function can work ,but when I use (nRF Connect...
Hi,
Due to shortage of pins SPI CS is reconfigured as GPIO while SPI is not used. Soft device is not used.
Problem is the delay that is needed after nrfx_spis_uninit call...
Hi,
I working with NRF52840 DK board, I need to read some potentiometer values or any sensor values and also send me the example code ADC with Bluetooth. I need to transfer...
1) Our device uses NRF52832 to connect with Android 7 system,use wireshark to monitoring,find not hop,is OK? and wireshark delta time is Connection Interval ?
2) nrf52832...
Summary
Construction of a cordova based cross platform mobile app that displays heart rate measurement data sent by a Nordic nRF51822 device via BLE. This data is periodically posting this to thingspeak…
Here is an example of a hardware setup to measure the voltage on a Lithium battery with a voltage divider on nRF52. The Lithium battery typically has a voltage range of 2.7 - 4.2 V and we (Nordic) recommend…
This series of posts will describe a new toy here at Nordic: The nRF Hexapod. The post will be divided in multiple parts, this part describing the project in general and the hardware that is required…
This blog series was created as an attempt to fill in the gap between how Bluetooth Smart is described in the spec and how you can use our APIs and event from our softdevice to do what defined in the spec…
Important updates:
Due to erratum 84 (COMP: ISOURCE not functional), capacitive sensing using the relaxation oscillator method is not usable in a real product with the nRF52832, as it will only work reliably…
This blog series was created as an attempt to fill in the gap between how Bluetooth Smart is defined in the spec and how you can use our APIs and event from our softdevice to do what defined in the spec…
###Other relevant posts
For an overview of current measurement basics, see this post: Introduction
For a concise guide to setting up measurement equipment with the nRF52832 development kit, see this…
###Other relevant posts
For an overview of current measurement basics, see this post: Introduction
A post that describes how to measure current on the nRF52821 Engineering B with SoftDevice s132 v2…
###Other relevant posts
A concise guide to equipment setup, and how to use the development kit for current measurements can be found here: Measuring current with PCA10040 v0.9.0
A post that describes…