Hi,
I am trying to power off and/or disable a RR[0] with no success.
I am Powering OFF the watchdog in main and then successfully POWERing ON in wdt_init but then I...
Is it possible when using the S110 softdevice to limit the maximum number of packets per connection event? I would like to reduce the maximum amount of time the CPU spends...
I am using nRF51422 Evaluation Kit with the latest silicon revision which comes with programmable softdevice. The kit also contains an ANT USB-m dongle. I have followed the...
I tried to do send & receive binary data from bluetooth in ios app.
But i only can send & receive string or ASCII code data in my app, do you have any method or idea can...
Hi,
I tried ble_app_hids_mouse with Android 4.4.2, it can work properly for first time connection. However, it cannot be re-connected after switching Phone's Bluetooth...
1.Profile
During connection procedure of BLE, there are three packages: SCAN_REQ, SCAN_RSP 和 CONNECT_REQ。
SCAN_REQ: Scan request, issued by MASTER DEVICE, send to SLAVE DEVICE,sent by the Link Layer…
1.Profile
MTU: ATT Maximum Transmission Unit (MTU) is the maximum length of an ATT packet. The ATT MTU is defined by the L2CAP and can be
anywhere between 23 and infinity. The implementation of the…
Today I tried to find the better ways to debug program on nRF52840 PDK from CLI on linux.
The ways that I tried
[Failed] openocd (both stlink and jlink) & gdb
[Succeeded] JLink & JLinkGDBServer &…
This blog series was created as an attempt to fill in the gap between how Bluetooth Smart is described in the spec and how you can use our APIs and event from our softdevice to do what defined in the spec…
Important updates:
Due to erratum 84 (COMP: ISOURCE not functional), capacitive sensing using the relaxation oscillator method is not usable in a real product with the nRF52832, as it will only work reliably…
This blog series was created as an attempt to fill in the gap between how Bluetooth Smart is defined in the spec and how you can use our APIs and event from our softdevice to do what defined in the spec…
###Other relevant posts
For an overview of current measurement basics, see this post: Introduction
For a concise guide to setting up measurement equipment with the nRF52832 development kit, see this…
###Other relevant posts
For an overview of current measurement basics, see this post: Introduction
A post that describes how to measure current on the nRF52821 Engineering B with SoftDevice s132 v2…
###Other relevant posts
A concise guide to equipment setup, and how to use the development kit for current measurements can be found here: Measuring current with PCA10040 v0.9.0
A post that describes…