I thought this should be very simple but it has not turned out that way. I have started with the pc-ble-driver heart rate monitor (peripheral) example. I was able to take...
Hi,
I building a gas meter monitor ( peripheral ) that transmit meter reading to the Central.
The gas meter will be sending to the Central it's ID and meter value ( uint64_t...
The International Conference on Embedded Wireless Systems and Networks will host also this year a dependability competition to benchmark the performance of state-of-the-art...
Hi,
I find the CSCS example program reading zero at low cadence levels below around 50 rpm.
Using ble_peripheral example ble_app_cscs loaded into the PCA10040 board or...
It's an old chestnut the pairing conundrum, how to make it safe and secure yet so simple people aren't left confused and frustrated whilst trying to pair products. Bluetooth Smart currently has 3 pairing…
When I decided to attempt the reprogramming of my nRF51822 Beacon Kit I read several posts related to the task. The information I needed was there but I found it to be a bit scattered. It was difficult…
The Infocenter – our new documentation portal - has now been up and running since June and contains all of our technical documentation. We saw the need for this because we wanted to make our complete…
This blog series was created as an attempt to fill in the gap between how Bluetooth Smart is described in the spec and how you can use our APIs and event from our softdevice to do what defined in the spec…
Important updates:
Due to erratum 84 (COMP: ISOURCE not functional), capacitive sensing using the relaxation oscillator method is not usable in a real product with the nRF52832, as it will only work reliably…
This blog series was created as an attempt to fill in the gap between how Bluetooth Smart is defined in the spec and how you can use our APIs and event from our softdevice to do what defined in the spec…
###Other relevant posts
For an overview of current measurement basics, see this post: Introduction
For a concise guide to setting up measurement equipment with the nRF52832 development kit, see this…
###Other relevant posts
For an overview of current measurement basics, see this post: Introduction
A post that describes how to measure current on the nRF52821 Engineering B with SoftDevice s132 v2…
###Other relevant posts
A concise guide to equipment setup, and how to use the development kit for current measurements can be found here: Measuring current with PCA10040 v0.9.0
A post that describes…