When I was using the device as peripheral, I was wondering when the Softdevice notified BLE_GAP_EVT_SEC_PARAMS_REQUEST and BLE_EVT_SEC_INFO_REQUEST:
1, when peripheral...
hi dear nordic employee:
I tried to build the project ble_app_hrs_c(pca10040) by keil5
but I get an error :
._build\nrf52832_xxaa.sct(7): error: L6236E: No section...
Hi,
I am a bit confused about power consumption when using app_uart_fifo. To save power I put MCU to sleep in between each sent and received byte by using __WFE and __SEV...
Hi! I am building an android app for my project. I am using Proximity , UART and DFU from nrfToolbox app. I have 3 buttons on my home screen dedicated for each of them. I...
Dear Nordic employee:
1、 what do I have?
I have a thingy52 develop kit(nrf52832)
2、what is my purpose?
the quality of thingy52 audio demo is not good(iphone7)...
1.Profile
During connection procedure of BLE, there are three packages: SCAN_REQ, SCAN_RSP 和 CONNECT_REQ。
SCAN_REQ: Scan request, issued by MASTER DEVICE, send to SLAVE DEVICE,sent by the Link Layer…
1.Profile
MTU: ATT Maximum Transmission Unit (MTU) is the maximum length of an ATT packet. The ATT MTU is defined by the L2CAP and can be
anywhere between 23 and infinity. The implementation of the…
Today I tried to find the better ways to debug program on nRF52840 PDK from CLI on linux.
The ways that I tried
[Failed] openocd (both stlink and jlink) & gdb
[Succeeded] JLink & JLinkGDBServer &…
This blog series was created as an attempt to fill in the gap between how Bluetooth Smart is described in the spec and how you can use our APIs and event from our softdevice to do what defined in the spec…
Important updates:
Due to erratum 84 (COMP: ISOURCE not functional), capacitive sensing using the relaxation oscillator method is not usable in a real product with the nRF52832, as it will only work reliably…
This blog series was created as an attempt to fill in the gap between how Bluetooth Smart is defined in the spec and how you can use our APIs and event from our softdevice to do what defined in the spec…
###Other relevant posts
For an overview of current measurement basics, see this post: Introduction
For a concise guide to setting up measurement equipment with the nRF52832 development kit, see this…
###Other relevant posts
For an overview of current measurement basics, see this post: Introduction
A post that describes how to measure current on the nRF52821 Engineering B with SoftDevice s132 v2…
###Other relevant posts
A concise guide to equipment setup, and how to use the development kit for current measurements can be found here: Measuring current with PCA10040 v0.9.0
A post that describes…