Hi,
I use SDK v10, S110 v8 and dfu_dual_bank_ble_s100_pca10028. My application has dfu support.
I reset to bootloader from application after writing 0x0104 to dfu control...
I have a nRF51822 device.
When the connection interval is 50ms.
The transmission distance can up to 50m+.
But, when the connection interval is 1000ms.
The transmission...
Hi,
I have a simple question. It is possible to use the ble-sniffer nrf51822 on Kali Linux? I found a guide to use it on linux but I don't know if it is the same for Kali...
I've modified Nordic's "Nordic_Keyboard" sample to work with my custom board, just simple modifications to use custom_board.h rather than the default PC10028 configuration...
Hi,
I use HID application with S110 v8.0 profil.
I use BLE HID Keyboard example.
I put datas from smartphone to BOOT KEYBOARD OUTPUT REPORT and I whant read them by...
Summary
Construction of a cordova based cross platform mobile app that displays heart rate measurement data sent by a Nordic nRF51822 device via BLE. This data is periodically posting this to thingspeak…
Here is an example of a hardware setup to measure the voltage on a Lithium battery with a voltage divider on nRF52. The Lithium battery typically has a voltage range of 2.7 - 4.2 V and we (Nordic) recommend…
This series of posts will describe a new toy here at Nordic: The nRF Hexapod. The post will be divided in multiple parts, this part describing the project in general and the hardware that is required…
This blog series was created as an attempt to fill in the gap between how Bluetooth Smart is described in the spec and how you can use our APIs and event from our softdevice to do what defined in the spec…
Important updates:
Due to erratum 84 (COMP: ISOURCE not functional), capacitive sensing using the relaxation oscillator method is not usable in a real product with the nRF52832, as it will only work reliably…
This blog series was created as an attempt to fill in the gap between how Bluetooth Smart is defined in the spec and how you can use our APIs and event from our softdevice to do what defined in the spec…
###Other relevant posts
For an overview of current measurement basics, see this post: Introduction
For a concise guide to setting up measurement equipment with the nRF52832 development kit, see this…
###Other relevant posts
For an overview of current measurement basics, see this post: Introduction
A post that describes how to measure current on the nRF52821 Engineering B with SoftDevice s132 v2…
###Other relevant posts
A concise guide to equipment setup, and how to use the development kit for current measurements can be found here: Measuring current with PCA10040 v0.9.0
A post that describes…